- Guaranteed Secure Payments on Every Order
- Refund if your item is not delivered or as described
- Buyer Protection after order confirmation
- Place of Origin: ZHANG QIU
- Brand Name: gas generator
- Model Number: LN
Natural gas---Its main component is Methane (CH4), which takes 90% of the whole content. The displacement of Nitrogen oxides (NOx), Hydrocarbon (CHm) and Carbon monoxide (CO), from burning are much lower than the state standards and without dust pollution; Thermal efficiency of conversion is 65%, which is same to the LPG and higher than Coal; Calculated on the same calorific value, the price of natural gas is lower than the price of coal and petroleum. Natural gas is used by civil use, generation, industrial chemicals and industrial fuel etc. It’s a good substitute of coal and petroleum. It can instead of civil coal gas; it can be used as nitrogenous fertilizer instead of coal and petroleum: it can be used as ethylene instead of Naphtha; it can be used as the car engine fuel instead of petroleum.
Requirements for natural gas(Within 1m from pressure regulating value of gas intake)
The ratio of Methane (CH4) in natural gas ≥70%;
Pressure of natural gas: 80—200kpa; rate of pressure change≤1kpa/min;
H2S≤20mg/Nm3;
Moisture content≤40g/Nm3;
Impurity particle size≤5μm, impurity content ≤30mg/Nm3
If fuel gas contains higher quantity of sulfur and ammonia, it not only corrodes the pole of spark plug seriously, but also increases acid value, which corrodes internal parts of genset and corrodes the genset with precipitates.
Application Place
Oil field
Industrial Zone
Petroleum chemical plant
Used as standby power source instead of Natural gas generating
Supply power for the auxiliary engine which in oil well
Small-medium power series natural gas genset
Main specification of natural gas genset
Mode Type | Small-medium power series Natural gas gen-set Ⅰ | Small-medium power series Natural gas gen-set Ⅱ |
Power | 20—200kw | 100—300kw |
Rated speed | 1500r/min | 1000r/min |
voltage | 400V/230V | 400V/230V |
Frequency | 50Hz | 50Hz |
Exciting method | Brushless | Brushless |
Voltage regulation mode | Automatic | Automatic |
Phase | AC3—phase. 4wire | AC3—phase. 4wire |
Application areas | Natural gas, associated gas | Natural gas, associated gas |
Main technical parameters of natural gas genset
Rated Voltage | 400V/230V |
Phase | 3 phase, 4 wire |
Rated frequency | 50Hz |
Rated speed | 1500r/min |
Power Factor | 0.8 |
Steady Voltage Adjusting Rate | ≤±2% |
Transient frequency adjusting rate | ≤±210% |
Voltage Stable time | ≤1S |
Fluctuation ratio of voltage | ≤±0.5% |
Steady frequency adjusting rate | ≤0.5% |
Transient frequency adjusting rate | ≤±10% |
Exhaust temperature | ≤650℃ |
Heat Consumption | ≤11.38mj/kw•h |
Gas Pressure | 120-200kpa |
Intake Mode | Naturally aspirated |
Sparking Mode | Spark plug |
Voltage Regulation Mode | Automatic |
Speed Regulation Mode | Electronic speed regulate |
Lubricating Mode | Pressure and splash |
Cooling Mode | Circulating water cooling |
Start Mode | 24 electric motor |
Noise | ≤105 dB(A) |
Overhaul time(H) | ≥3000h |
- Place of Origin: ZHANG QIU
- Brand Name: gas generator
- Model Number: LN
Technical parameters of natural gas genset
Model NO. | LN400GF-T | LN500GF-T | LN600GF-T |
Engine NO. | 12V190DT-2 | 12V190ZLDT-2 | 12V190ZLDT-2 |
Gas Mix Type | outside | outside | outside |
Rated Power | 400kw | 500kw | 600kw |
Prime Power | 320kw | 400kw | 480kw |
Rated Voltage | 400V/230V | 400V/230V | 400V/230V |
Phase | 3 phase, 4 wire | 3 phase, 4 wire | 3 phase, 4 wire |
Rated Frequency | 50Hz | 50Hz | 50Hz |
Rated Speed | 1000r/min | 1000r/min | 1000r/min |
Rated Power Factor | 0.8 | 0.8 | 0.8 |
Rated Current | 720A | 902A | 1080A |
Steady Voltage Adjusting Rate | ≤±2% | ≤±2% | ≤±2% |
Transient voltage adjusting rate | ≤±10% | ≤±10% | ≤±10% |
Voltage Stable time | ≤1S | ≤1S | ≤1S |
Fluctuation ratio of voltage | ≤±0.5% | ≤±0.5% | ≤±0.5% |
Steady frequency adjusting rate | ≤0.5% | ≤0.5% | ≤0.5% |
Transient frequency adjusting rate | ≤±10% | ≤±10% | ≤±10% |
Frequency Recovery Time | ≤3s | ≤3s | ≤3s |
Frequency Fluctuation Rate | ≤0.5% | ≤0.5% | ≤0.5% |
Voltage regulating Rate | 95-105% | 95-105% | 95-105% |
Heat Consumption | ≤11.38Mj/kw•h | ≤11.38 Mj/kw•h | ≤11.38 Mj/kw•h |
Lubricant Consumption | 1.0~1.63g/kw•h | 1.0~1.63g/kw•h | 1.0~1.63g/kw•h |
Gas Pressure | 120-200kpa | 120-200kpa | 120-200kpa |
Cylinder Number | Vshape, 12cylinders | V shape, 12 cylinders | V shape, 12 cylinders |
Cylinder Diameter | 190mm | 190mm | 190mm |
Stork | 210mm | 210mm | 210mm |
Starting Mode | 24V electric motor | 24V electric motor | 24V electric motor |
Overhaul Period | ≥30000h | ≥30000h | ≥30000h |
Noise | ≤105 dB(A) | ≤105 dB(A) | ≤105 dB(A) |
Intake mode | Naturally intake | Supercharging, inter cooler | Supercharging, inter cooler |
Ignition Mode | Spark plug | Spark plug | Spark plug |
Pressure Regulation Mode | Automatic pressure regulation | Automatic pressure regulation | Automatic pressure regulation |
Speed Regulation Mode | Electronic speed regulation | Electronic speed regulation | Electronic speed regulation |
Lubrication Mode | Pressure and splash lubrication | Pressure and splash lubrication | Pressure and splash lubrication |
Cooling Mode | Closed / open cooling | Closed / open cooling | Closed / open cooling |
Exhaust Temperature | ≤650℃ | ≤650℃ | ≤650℃ |
Displacement | 71.45L | 71.45L | 71.45L |
Size | 6000×1970×2732mm | 6000×1970×2732mm | 6000×1970×2732mm |
Genset Weight | 11000kg | 111500kg | 12000kg |